POWER TRIM
Page 5B-38 90-855347R1 JANUARY 1999
Motor and Electrical Tests/Repair
Trim Pump Motor Test
WARNING
Do not perform this test near flammable materials, as a spark may occur while
making electrical connections.
1. Connect a 12 volt power supply to motor wires; one motor lead to POSITIVE (+) bat-
tery terminal and the other motor lead to the NEGATIVE (–) battery terminal. Motor
should run. Reverse motor leads between battery terminals. Motor should run.
53774
2. If motor does not run, disassemble and check components.
Motor Disassembly
1. Remove 2 screws.
53774
a
a
a-Screw (2)