6 - ORDINARY MAINTENANCE
6 - 14
EVERY 10 HOURS OR DAILY
• HYDRAULIC OIL
To check the hydraulic oil level it is necessary to:
- place the machine on a perfectly even ground
- lower and retract the telescopic boom completely
- switch off the Diesel engine
- use indicator "A" to check that the hydraulic oil level is between the minimum
(MIN) and the maximum (MAX) level.
- if necessary, remove the filler cap (B) and top up (also see paragraph FUELS
AND LUBRICANTS).
NOTE! To ensure the machine's optimum performance, regularly
check the oil level in the hydraulic system, and top up the oil if necessary.
• HYDROSTATIC TRANSMISSION OIL
Check the level of the hydrostatic transmission oil present in tank "A".
WARNING!! Do not remove cap "B" unless the engine is cold.
Release all pressure before fully removing the cap.
The hydrostatic oil level must be visible in the indicator glass "C", located near the
drain plug.
If the level is low, add specific oil (also see paragraph FUELS AND LUBRICANTS).
Re-tighten cap "B" and check for any leak in the system.
• COOLING SYSTEM
Check the engine coolant level.
CAUTION !!! Do not remove cap "B" unless the engine is cold. Release all pressure before fully removing the
cap. For further information, refer to the attached engine manual.
The coolant level in the expansion tank "A" must be between the "MIN" and "MAX" marks indicated on the tank.
If the engine coolant level is low, top up with a coolant available on the market.
Tighten the filler cap and check the cooling system for loose connections and leaks.