– 3.18 –
DISPLAY
This function is used to change over the language used to give displays on the LCD.
Setting value
Japanese
English
•German
•French
Spanish
Italian
Portuguese
Setting communication conditions [INTERFACE]
This function is used to establish communication conditions of the RS-232C interface.
Settings of the communication conditions differ with the command (AUTO, MGL-I c1 or MGL-II
c) specified using the command change-over function.
* If you have changed the step size, be sure to raise the pinch rollers using the sheet
set lever and re-load the sheet on the device.
Setting value (Make a choice and input it)
Baud rate : 1200, 4800, 9600, 19200, 38400 (bps)
Data bit : 7, 8 (bit)
Parity : NON, EVEN, ODD
Stop bit : 1, 1.5, 2 (bit)
Handshake : HARD, SOFT, X-PRM, SOFT
Step size : 0.025, 0.01 (mm)
Parallel : NORMAL, BUFFER
Close time : 3 to 60 (sec.)
[PARALLEL]
This designates the operating procedure of the 8-bit parallel interface.
NORMAL : The device receives data and performs cutting at a time.
BUFFER : The device starts cutting under any of the following states.
•When the device receives 800 Kbytes data under the remote mode
•When the device received certain data and has not received additional data
for two seconds or more.