Introduction Product Description
2 - 2 Operator’s Manual of Anesthesia System
2.1 Introduction
2.1.1 Indications For Use
The Anesthesia System is a device used to administer to a patient, continuously or intermittently, a
general inhalation anesthetic and to maintain a patient's ventilation.
The Anesthesia System is intended for use by licensed clinicians in the administration of general
anesthesia, for patients requiring anesthesia within a health care facility, and can be used in adult,
pediatric and neonate populations.
High Flow Nasal Cannula (HFNC) is indicated for delivery of nasal high flow oxygen to spontaneously
breathing adult patients. It can be used for pre-oxygenation and short-term supplemental
oxygenation (up to 10 minutes) during intubation in operating rooms. It is not intended for apneic
ventilation. HFNC is indicated for use in adults only.
WARNING: This anesthesia system is intended for use by qualified anesthesia
personnel only or under their guidance. Personnel for using the
equipment should receive complete pre-use training. Unauthorized
personnel, or personnel who have received no training, must not
perform any operations on the equipment.
WARNING: The equipment is not suitable for use in an MRI environment.
2.1.2 Structure and Composition
The Anesthesia System consists of main unit, anesthetic ventilator, anesthetic gas delivery system, anesthetic
breathing system (including the airway pressure gauge, volume exchanger, CO
2
absorbent canister, inspiratory
and expiratory check valves, inspiratory and expiratory flow sensors, exhaust valve, Auto/Manual switch,
manual bag port, inspiratory and expiratory ports and connectors), Anesthetic Gas Scavenging System (AGSS),
negative pressure suction device, anesthetic gas monitoring module, O
2
cell and accessories.
2.1.3 Functions and Features
The anesthesia system is intended to provide continuous or intermittent general inhalation
anesthesia and maintain ventilation for patients. This equipment also provides ventilation monitoring
for patients. The anesthesia system is applicable to patient environments.
Applied parts of the anesthesia system are the breathing tubes and masks. Connect the patient to
the Anesthesia System via the breathing circuit. The anesthesia system provides the following
ventilation modes:
Manual ventilation
Volume Control Ventilation (VCV)
Pressure Controlled Ventilation
Pressure Controlled Ventilation (PCV)
Pressure Controlled Ventilation-Volume Guarantee (PCV-VG)
Synchronized Intermittent Mandatory Ventilation (SIMV)
Synchronized Intermittent Mandatory Ventilation – Volume Control (SIMV-VC)
Synchronized Intermittent Mandatory Ventilation – Pressure Control (SIMV-PC)
Synchronized Intermittent Mandatory Ventilation – Volume Guarantee (SIMV-VG)
Continuous Positive Airway Pressure/Pressure Support Ventilation (CPAP/PS)
Airway Pressure Release Ventilation (APRV) (optional)
The anesthesia system provides the following frequently-used features or configurations:

Table of Contents

Other manuals for Mindray A9

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray A9 and is the answer not in the manual?

Mindray A9 Specifications

General IconGeneral
BrandMindray
ModelA9
CategoryMedical Equipment
LanguageEnglish

Related product manuals