Anesthesia System
ANESTHESIA SYSTEM
Service Manual
|

Table of Contents

Other manuals for Mindray A9

Questions and Answers:

Mindray A9 Specifications

General IconGeneral
TypeAnesthesia Workstation
Integrated Gas AnalysisYes
Backup BatteryYes
Operating Temperature10°C to 40°C
Storage Temperature-20°C to 55°C
Battery TypeLithium-ion
Ventilation ModesVolume Control, Pressure Control, SIMV, Manual Ventilation
DisplayTouchscreen
Patient MonitoringECG, SpO2, NIBP, EtCO2, Temperature
ConnectivityEthernet, USB
PortabilityMobile (with wheels)
Battery LifeMinimum 90 minutes (typical)
AltitudeUp to 3000 meters
Power Supply100-240 VAC, 50/60 Hz
Charging TimeApproximately 4 hours
StorageInternal storage for patient data and system logs
Supported LanguagesMultiple languages
CertificationsCE, FDA

Summary

1 Safety

1.1 Safety Information

Provides crucial safety information including DANGER, WARNING, CAUTION, and NOTE definitions for safe operation.

5 Testing

5.1 Power-on Self-Test

Details the self-test procedure to ensure alarm system and hardware functionality upon power-on.

5.2 System Check

Describes system check modes including power-on self-test, leak test, and vaporizer test.

5.3 Gas Supply Tests

Provides procedures for testing O2, N2O, and AIR gas supply functionality.

5.4 Cylinder Supply Tests

Outlines tests for N2O, O2, and AIR cylinder supplies to ensure proper pressure and function.

5.7 Electronic Vaporizer Test (A9 only)

Details tests for the electronic vaporizer, including monitoring function, self-locking, interlock, and accuracy.

5.8 Mechanical Vaporizer Test (A8 only)

Describes tests for the mechanical vaporizer, covering interlock, back pressure, accuracy, and leak tests.

5.13 Alarm Tests

Details tests for various alarms including power failure, breathing circuit, O2 supply failure, and ventilator-related alarms.

5.14 System Ventilation Performance Tests

Covers tests for manual, VCV adult, VCV pediatric, and PCV adult ventilation modes.

5.18 Electrical Tests

Includes tests for auxiliary power receptacles, work lights, and electrical safety inspection.

6 System Calibration

6.3 System Calibration

Details various calibration procedures including flow, O2 sensor, flowmeter zeroing, and pressure calibration.

7 Troubleshooting

7.2 Power-On Troubleshooting

Addresses issues related to power-on and display failures, and auxiliary outlet failures.

8 Repair and Disassembly

9 Software Upload

10 Software Function Activation

11 FRUs