EasyManuals Logo
Home>Mindray>Medical Equipment>A9

Mindray A9 Service Manual

Mindray A9
424 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
3
5.12 Negative Pressure Suction Tests .................................................................................. 5-17
5.13 Alarm Tests .................................................................................................................. 5-17
5.13.1 Power Failure Alarm Test ............................................................................... 5-17
5.13.2 Breathing Circuit Alarm Tests ........................................................................ 5-17
5.13.3 O2 Supply Failure and Balance Gas Branch Flow Not Achieved Alarm Tests5-18
5.13.4 Ventilator-Related Alarm Tests ....................................................................... 5-19
5.14 System Ventilation Performance Tests ........................................................................ 5-21
5.14.1 Manual Mode Ventilation Test ....................................................................... 5-21
5.14.2 VCV Adult Ventilation Mode Test ................................................................. 5-21
5.14.3 VCV Pediatric Ventilation Mode Test ............................................................ 5-22
5.14.4 PCV Adult Ventilation Mode Test .................................................................. 5-23
5.15 Sensor Zero Point Check ............................................................................................. 5-23
5.16 Constant Flow Test (Checking the Flow Sensor Accuracy) ........................................ 5-24
5.17 Constant Flow Test (Checking the Pressure Sensor Accuracy) ................................... 5-25
5.18 Electrical Tests ............................................................................................................ 5-27
5.18.1 Auxiliary Power Receptacle Test .................................................................... 5-27
5.18.2 Work Light Test .............................................................................................. 5-27
5.18.3 Electrical Safety Inspection Test .................................................................... 5-28
6 System Calibration ........................................................................................................... 6-1
6.1 Overview ......................................................................................................................... 6-1
6.2 Precautions ...................................................................................................................... 6-1
6.2.1 Warnings ............................................................................................................. 6-1
6.2.2 Cautions ............................................................................................................. 6-2
6.2.3 Notes .................................................................................................................. 6-2
6.3 System Calibration .......................................................................................................... 6-3
6.3.1 Flow Calibration (User) ..................................................................................... 6-5
6.3.2 O2 Sensor Calibration (User) ........................................................................... 6-12
6.3.3 Flowmeter Zeroing (User) ................................................................................ 6-20
6.3.4 High-flow O2 Supply Zeroing (User) .............................................................. 6-23
6.3.5 Pressure Calibration (Service) .......................................................................... 6-27
6.3.6 Expiratory Valve Calibration (Service) ............................................................ 6-39
6.3.7 Pressure and Flow Zeroing (Service) ............................................................... 6-43
6.3.8 Total Flow Sensor Calibration (Service) .......................................................... 6-46
6.3.9 Internal AG Calibration (User) ......................................................................... 6-51
6.3.10 External AG Calibration (User) ...................................................................... 6-52
6.3.11 NMT Sensor Check (User) (Canada Only) .................................................... 6-53
6.3.12 Vaporizer Injector Calibration (Service) (A9 Only) ....................................... 6-56
6.4 Tests After Calibration .................................................................................................. 6-62
7 Troubleshooting ................................................................................................................ 7-1
7.1 Precautions ...................................................................................................................... 7-1
7.2 Power-On Troubleshooting ............................................................................................. 7-1
7.2.1 Power-On and Display Failures ......................................................................... 7-1
7.2.2 Auxiliary Outlet Failures .................................................................................... 7-2
7.2.3 Leak Test Failures in Auto Mode ....................................................................... 7-2
7.2.4 Leak Test Failures in Manual Mode ................................................................... 7-4
7.3 Technical Alarms ............................................................................................................. 7-5
7.3.1 Power-On Self-Test Alarms ................................................................................ 7-5
7.3.2 CPU Board Runtime Alarms ............................................................................. 7-11
7.3.3 Power Board Runtime Alarms .......................................................................... 7-12
7.3.4 Electronic Flowmeter and BFCS Runtime Alarms .......................................... 7-15
7.3.5 VCM Runtime Alarms ..................................................................................... 7-20

Table of Contents

Other manuals for Mindray A9

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray A9 and is the answer not in the manual?

Mindray A9 Specifications

General IconGeneral
BrandMindray
ModelA9
CategoryMedical Equipment
LanguageEnglish

Related product manuals