3
5.12 Negative Pressure Suction Tests .................................................................................. 5-17
5.13 Alarm Tests .................................................................................................................. 5-17
5.13.1 Power Failure Alarm Test ............................................................................... 5-17
5.13.2 Breathing Circuit Alarm Tests ........................................................................ 5-17
5.13.3 O2 Supply Failure and Balance Gas Branch Flow Not Achieved Alarm Tests5-18
5.13.4 Ventilator-Related Alarm Tests ....................................................................... 5-19
5.14 System Ventilation Performance Tests ........................................................................ 5-21
5.14.1 Manual Mode Ventilation Test ....................................................................... 5-21
5.14.2 VCV Adult Ventilation Mode Test ................................................................. 5-21
5.14.3 VCV Pediatric Ventilation Mode Test ............................................................ 5-22
5.14.4 PCV Adult Ventilation Mode Test .................................................................. 5-23
5.15 Sensor Zero Point Check ............................................................................................. 5-23
5.16 Constant Flow Test (Checking the Flow Sensor Accuracy) ........................................ 5-24
5.17 Constant Flow Test (Checking the Pressure Sensor Accuracy) ................................... 5-25
5.18 Electrical Tests ............................................................................................................ 5-27
5.18.1 Auxiliary Power Receptacle Test .................................................................... 5-27
5.18.2 Work Light Test .............................................................................................. 5-27
5.18.3 Electrical Safety Inspection Test .................................................................... 5-28
6 System Calibration ........................................................................................................... 6-1
6.1 Overview ......................................................................................................................... 6-1
6.2 Precautions ...................................................................................................................... 6-1
6.2.1 Warnings ............................................................................................................. 6-1
6.2.2 Cautions ............................................................................................................. 6-2
6.2.3 Notes .................................................................................................................. 6-2
6.3 System Calibration .......................................................................................................... 6-3
6.3.1 Flow Calibration (User) ..................................................................................... 6-5
6.3.2 O2 Sensor Calibration (User) ........................................................................... 6-12
6.3.3 Flowmeter Zeroing (User) ................................................................................ 6-20
6.3.4 High-flow O2 Supply Zeroing (User) .............................................................. 6-23
6.3.5 Pressure Calibration (Service) .......................................................................... 6-27
6.3.6 Expiratory Valve Calibration (Service) ............................................................ 6-39
6.3.7 Pressure and Flow Zeroing (Service) ............................................................... 6-43
6.3.8 Total Flow Sensor Calibration (Service) .......................................................... 6-46
6.3.9 Internal AG Calibration (User) ......................................................................... 6-51
6.3.10 External AG Calibration (User) ...................................................................... 6-52
6.3.11 NMT Sensor Check (User) (Canada Only) .................................................... 6-53
6.3.12 Vaporizer Injector Calibration (Service) (A9 Only) ....................................... 6-56
6.4 Tests After Calibration .................................................................................................. 6-62
7 Troubleshooting ................................................................................................................ 7-1
7.1 Precautions ...................................................................................................................... 7-1
7.2 Power-On Troubleshooting ............................................................................................. 7-1
7.2.1 Power-On and Display Failures ......................................................................... 7-1
7.2.2 Auxiliary Outlet Failures .................................................................................... 7-2
7.2.3 Leak Test Failures in Auto Mode ....................................................................... 7-2
7.2.4 Leak Test Failures in Manual Mode ................................................................... 7-4
7.3 Technical Alarms ............................................................................................................. 7-5
7.3.1 Power-On Self-Test Alarms ................................................................................ 7-5
7.3.2 CPU Board Runtime Alarms ............................................................................. 7-11
7.3.3 Power Board Runtime Alarms .......................................................................... 7-12
7.3.4 Electronic Flowmeter and BFCS Runtime Alarms .......................................... 7-15
7.3.5 VCM Runtime Alarms ..................................................................................... 7-20

Table of Contents

Other manuals for Mindray A9

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray A9 and is the answer not in the manual?

Mindray A9 Specifications

General IconGeneral
TypeAnesthesia Workstation
Integrated Gas AnalysisYes
Backup BatteryYes
Operating Temperature10°C to 40°C
Storage Temperature-20°C to 55°C
Battery TypeLithium-ion
Ventilation ModesVolume Control, Pressure Control, SIMV, Manual Ventilation
DisplayTouchscreen
Patient MonitoringECG, SpO2, NIBP, EtCO2, Temperature
ConnectivityEthernet, USB
PortabilityMobile (with wheels)
Battery LifeMinimum 90 minutes (typical)
AltitudeUp to 3000 meters
Power Supply100-240 VAC, 50/60 Hz
Charging TimeApproximately 4 hours
StorageInternal storage for patient data and system logs
Supported LanguagesMultiple languages
CertificationsCE, FDA