6-20 Mx100/200 Series Operation Manual
* Block Execution
Pattern: Applied to Matrix and Non-Matrix types. PWB is processed on block base.
Step: All blocks are processed by point on PWB block (default).
Overall: Several PWB blocks are combined into one block.
* Stopper Usage
Main: Uses the Main Stopper (Recommended for PWB 200mm or more).
Center: Uses the Center Stopper (Recommended for length less than 200mm)
This option is applicable only to those systems equipped with a Center Stopper (120 series