3-6
C-Feeder User Manual
Trouble shooting guide during production
If the feeder action is not performed fluently, check the following points.
Foreign substance in the
auto
Display LED
remains off
when a feeder is
mounted to the
machine.
plug pin in the front of
feeder. Foreign substance in
interface of the slot.
Auto plug pin is stuck inside
the feeder
Replace auto plug pin assy
Power supply from the
machine to the feeder
Press the feeder power button.
No problem in operating the
machine. Needs to replace the
board.
Feeding fails
and red LED on
the feeder is on.
The same error occurs even
when it is mounted on other
slots
Damage in feeder board
Harness cut off
Feeding fails
(No red LED)
Does the system read the
feeder properly?
Read feeder data on the Intelligent
Feeder Menu.
Resistance in rear part
Check if reel turns properly
on the reel hanger
Check the feeder from a side of the
feeder and remove the problem of
catch between reel hanger and reel
cover
Resistance in the front part
Remove the cause of catch inside
the reel cover or reel discharge.
Incorrect
picking position
Teaching of auto feeding
point
Feeding position may be changed
due impact of locking. Set the reel,
perform auto feeding, and give
teacing of the auto feeding
position Perform production after
feeding once when the feeder is
mounted.