EasyManua.ls Logo

Mitel 470 - Page 226

Mitel 470
272 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation and Maintenance
226
Mitel 470 as of R4.1
syd-0585/1.2 – R4.1 – 08.2016
ESME reachable The LAN connection between the SMSC and the
ESME is now available
IP address, date,
time
critical
(positive,
with
match)
ESME unreachable The LAN connection between the SMSC and the
ESME is interrupted
IP address, date,
time
critical
(negative,
with
match)
Ethernet activated again The overload on the Ethernet interface no longer
exists. The interface has been reactivated.
Date, time
Normal
(positive,
with
match)
Ethernet deactivated due to
high load
The system has detected an overload on the
Ethernet interface. The interface is temporarily
deactivated.
Date, time
Normal
(negative,
with
match)
External auxiliary power sup-
ply failed (Mitel 470 only)
The external auxiliary power supply to the com-
munication server has failed. If the auxiliary
power supply unit has been used for redundant
operation, there are no short-term limitations. If
the auxiliary power supply unit has been used to
increase the power supply, the internal power
supply unit overflow must be calculated.
Date, time
Normal
(negative,
with
match)
External auxiliary power sup-
ply in service (Mitel 470 only)
The external auxiliary power supply to the com-
munication server is working.
Date, time
Normal
(positive,
with
match)
External event message des-
tination not reachable
External signal destination not automatically
reachable
Cause (0: Busy
/1: Not available
/2:(not used),
2: Barred /3: not
defined), date, time
Serious
(negative,
with
match)
External event message des-
tination reachable
External signal destination is now reachable Date, time
Serious
(positive,
with
match)
Fan failure (Mitel 415/430
only)
The fan is jammed or defective or the connection
is no longer making contact.
Parameter = 0: No more fans in operation.
Risk of overheating: Replace defective fan.
Parameter, date,
time
critical
(negative,
with
match)
Event message Trigger condition Details
1)
Severity

Table of Contents

Related product manuals