Operation and Maintenance
249
Mitel 470 as of R4.1
syd-0585/1.2 – R4.1 – 08.2016
6. 6. 2. 7 Malfunctions of the DECT charging bays
Tab. 106 Malfunctions of the DECT charging bay
A cordless phone is called from a different system
phone, but cannot be reached.
Busy tone obtained and display reads Busy
Cordless phone is busy
Congestion tone obtained and display reads Circuit overload.
All radio channels busy
If congestion tone is obtained after 8 seconds and display
reads No answer. Reasons why the cordless phone could not
be reached:
•It is switched off
It is not within reachable radio area
No radio channels currently available
It is not registered with the system
Call diverted due to unobtainable
Cordless phone is not ringing. Activate tone ringing
The cordless phone cannot be configured; PIN miss-
ing (or forgotten).
Reset PIN for user (overwrite)
Error description Error cause / error handling
The cordless phone will not charge. Connect power supply
Check the charging contacts
Check battery and replace if necessary.
About the charging process:
Battery symbol on the cordless phone is flashing
(Office 135) or filling up (Office 160, Mitel 600 DECT) when
the battery is being charged.
Check tone indicates correct contact.
Error description Error cause / error handling