Operation and Maintenance
231
Mitel 470 as of R4.1
syd-0585/1.2 – R4.1 – 08.2016
NTP: Time synchronisation
re-established
Time synchronization via the NTP server (NTP =
Network Time Protocol) has been restored.
Date, time Serious
(positive,
with
match)
Outgoing call rejected Call rejected by the network
On any line: error code 34
On required line group:
error code 44
Port number of the
exchange line circuit,
cause, date, time
Normal
(without
match)
Overheat (Mitel 415/430
only)
The temperature inside the communication
server is too high. The appropriate measures
must be taken immediately to improve the heat
dissipation, e.g. by providing the required clear-
ances, lowering the ambient temperature or
installing the fan from the rack-mounting set
(Mitel 430 only).
Card number, tem-
perature, date, time
critical
(negative,
with
match)
Overheat (Mitel 470 only) The temperature inside the communication
server is too high. Appropriate measures must
be taken immediately to improve heat dissipa-
tion. Measures are automatically adopted,
depending on where the overheating occurs:
FXO and FXS interface card:
the ports are deactivated in groups of 4 ports.
Once they have cooled down below a defined
card-specific value, the ports are automatically
reactivated group by group.
CPU2 applications card
The card will be completely deactivated. Once
it has cooled down below a defined value, the
card is automatically reactivated.
Internal power supply unit PSU2U or call man-
ager card CPU1:
the communication server will be shut down
completely.
Notes:
To prevent the system from overheating, no
more than 30% of the FXS ports should be
active simultaneously per 32FXS card and no
more than 50 FXS ports per system.
PRI, BRI and DSI cards do not have tempera-
ture sensors and are therefore never deacti-
vated due to overheating.
Card number, tem-
perature, date, time
critical
(negative,
with
match)
Overload detected on USB
port (CPU2) (Mitel 470 only)
A (current) overload was detected on one of the
USB interfaces on the applications card (CPU2).
Note: The maximum current input at the USB
interfaces varies:
(see also Tab. 29
)
Date, time
Normal
(without
match)
Port out of service A port previously in operation has stopped func-
tioning.
Number of the slot,
relevant port number,
date, time
Normal
(without
match)
Event message Trigger condition Details
1)
Severity