Operation and Maintenance
233
Mitel 470 as of R4.1
syd-0585/1.2 – R4.1 – 08.2016
SMS gateway reachable External SMS gateway again reachable Date, time critical
(positive,
with
match)
SMS gateway unreachable External SMS gateway unobtainable by network
provider or incorrectly configured
Date, time
critical
(negative,
with
match)
Software upgrade IP system
phone failed
The software update of an MiVoice 5361 IP /
5370 IP / 5380 IP has failed for the stated rea-
son.
User number, termi-
nal ID, reason, date,
time
critical
(negative,
with
match)
Software upgrade IP system
phone successful
The software update of an MiVoice 5361 IP /
5370 IP / 5380 IP has now been successfully
completed after unsuccessful attempt(s).
User number, termi-
nal ID, date, time
critical
(positive,
with
match)
Software upload During an upload in system status:
• Update running
• Supervision running
• Normal operation
Parameter 1:
• 0: "New communi-
cation server soft-
ware loaded, start-
ing...",
• 1: New communi-
cation server soft-
ware crashed, roll-
back performed
• 3: New communi-
cation server soft-
ware started and
running well
Date, time
Normal
(without
match)
Standard SIP terminals within
the licence limit again
SIP Terminals and Video Terminals licences are
now available.
Parameter 1=1: SIP
Term inal s licence,
Parameter 2=1:
Video Terminals
licence, date, time
Serious
(positive,
with
match)
Synchronisation loss on trunk A BRI/PRI interface entered in the clock pool
has lost the system clock
Port number, date,
time
Serious
(negative,
with
match)
Synchronisation re-estab-
lished
Synchronization with the network has been
restored on at least one BRI/PRI interface.
Date, time
Serious
(positive,
with
match)
Event message Trigger condition Details
1)
Severity