234
12 FILE CONTROL
12.6 File Modification
Communication example (files for MELSEC-Q series)
Modify the date and time of file creation under the following conditions.
Drive No.: 0
Date to change: 2010/04/01
Time to change: 20:50:58
File name: ABC.QPG
Data communication in ASCII code
(Request data)
Data communication in binary code
(Request data)
1826
31
H
38
H
32
H
36
H
0000
30
H
30
H
30
H
30
H
0000
30
H
30
H
30
H
30
H
0007
30
H
30
H
30
H
37
H
3C81
33
H
43
H
38
H
31
H
A65D
41
H
36
H
35
H
44
H
0000
30
H
30
H
30
H
30
H
ABC
41
H
42
H
43
H
.QPG
2E
H
51
H
50
H
47
H
Subcommand (Fixed value) Drive No. Date to change Time to change
Number of
file name characters
File name
26
H
18
H
00
H
00
H
00
H
00
H
00
H
00
H
00
H
00
H
81
H
3C
H
5D
H
A6
H
07
H
00
H
ABC
41
H
42
H
43
H
.QPG
2E
H
51
H
50
H
47
H
Subcommand
Time to
change
Date to
change
Number of file name
characters
Drive
No.
(Fixed value)
File name