EasyManua.ls Logo

Mitsubishi Electric MELSEC iQ-R Series - Page 237

Mitsubishi Electric MELSEC iQ-R Series
498 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12 FILE CONTROL
12.6 File Modification
235
12
Communication example (files for MELSEC iQ-R series)
Modify the date and time of file creation under the following conditions.
Drive No.: 4
Date to change: 2010/04/01
Time to change: 20:50:58
The file name is as shown below.
(1) LINE.CSV (8 characters)
Data communication in ASCII code
(Request data)
Data communication in binary code
(Request data)
Item Value of code corresponds to character
File name L I N E . C S V
UTF-16 004C 0049 004E 0045 002E 0043 0053 0056
ASCII code 30303443 30303439 30303445 30303435 30303245 30303433 30303533 30303536
Binary code 4C00 4900 4E00 4500 2E00 4300 5300 5600
1826
31
H
38
H
32
H
36
H
0000
30
H
30
H
30
H
30
H
0004
30
H
30
H
30
H
34
H
0008
30
H
30
H
30
H
38
H
3C81
33
H
43
H
38
H
31
H
A65D
41
H
36
H
35
H
44
H
0040
30
H
30
H
34
H
30
H
(1)
Date to change Time to changeSubcommand (Fixed value) Drive No.
Number of file
name characters
File name
26
H
18
H
00
H
00
H
40
H
00
H
00
H
00
H
04
H
00
H
81
H
3C
H
5D
H
A6
H
08
H
00
H
(1)
Subcommand
Drive
No.
Date to
change
Time to
change
Number of file name
characters(Fixed value) File name

Table of Contents