 DEDICATED INSTRUCTIONS
10.4 ZP.UINI
10 - 26
9
PROGRAMMING
10
DEDICATED 
INSTRUCTIONS
11
TROUBLESHOOTINGAPPENDICESINDEX
(2) Control data
 * 1  The setting side is as described below.
 User    : Data are set by the user before dedicated instruction execution.
 System: The programmable controller CPU stores the result of dedicated instruction execution.
 * 2  When 1 is specified for the execution type, values set for (S1)+3 to (S1)+7 are ignored.
(a) Mode setting
Set the operation mode of the QJ71MB91.
Table10.16 Control data of the UINI instruction
Device Item Setting Data Setting range
Setting side
*1
(S1)+0 - Specify 0. 0User
(S1)+1
Completion
status
The status of the instruction completion is stored.
 0 : Normal completion
 Other than 0: Error completion (error code) (  Section 11.4.3)
- System
(S1)+2 Execution type
Specify an execution type.
   0: Change the settings to the values set in (S1)+3 to (S1)+7.
   1: Restore the intelligent function module switch settings set in GX Developer.
*2
0, 1 User
(S1)+3
CH1 mode 
setting
(switch 1)
Specify a mode for CH1.
 (  (2) (a))
0 to 2 User
(S1)+4
CH1 
communication 
speed setting/
transmission 
setting 
(switch 2)
Specify a communication speed and transmission details for CH1.
 (  (2) (b))
0 to 0B7E
H User
(S1)+5
CH2 mode 
setting 
(switch 3)
Specify a mode for CH2.
 (  (2) (a))
0 to 2 User
(S1)+6
CH2 
communication 
speed setting/
transmission 
setting 
(switch 4)
Specify a communication speed and transmission details for CH2.
 (  (2) (b))
0 to 0B7E
H User
(S1)+7
CH1/CH2 
station No. 
setting 
(switch 5)
Specify its own station No.
 (  (2) (c))
0 to F7H User
(S1)+8 to 
(S1)+12
-Specify 0. 0User
Table10.17 CH1/CH2 mode setting
Set value Operation mode Description
0000H Master function Performs communication as master station.
0001H Slave function Performs communication as slave station.
0002H Link operation (Slave function)
Relays data between CH1 and CH2 with the 
link operation function. (  Section 5.3.3)