NICE7000 User Manual 6 Function Code Table
- 107 -
Function
Code
Parameter Name Setting Range Default
Unit
Property
F3-20
Zero-speed control
time at end
0.000–1.000
0.300
s
★
F3-21
Brake apply delay 0.200–1.500
0.200s
s
★
Group F4: Floor parameters
F4-00
Leveling
adjustment
0–60
30
mm
★
F4-01
Current oor F6-01 to F6-00
1
-
★
F4-02
High byte of current
oor position
0–65535
0
Pulses
●
F4-03
Low byte of current
oor position
0–65535
0
Pulses
●
F4-04
Length 1 of leveling
plate
0–65535
0
mm
★
F4-05
Length 2 of leveling
plate
0–65535
0
mm
★
F4-06
Leveling delay 0–80
28
ms
★
F4-07
Down leveling
adjustment
0–60
30
mm
★
F4-10
High byte of oor
height 1
0–65535
0
Pulses
★
F4-11
Low byte of oor
height 1
0–65535
0
Pulses
★
F4-12
High byte of oor
height 2
0–65535
0
Pulses
★
F4-13
Low byte of oor
height 2
0–65535
0
Pulses
★
F4-14
High byte of oor
height 3
0–65535
0
Pulses
★
F4-15
Low byte of oor
height 3
0–65535
0
Pulses
★
F4-16
High byte of oor
height 4
0–65535
0
Pulses
★
F4-17
Low byte of oor
height 4
0–65535
0
Pulses
★
F4-18
High byte of oor
height 5
0–65535
0
Pulses
★
F4-19
Low byte of oor
height 5
0–65535
0
Pulses
★
Floor height 6 to oor height 53
F4-116
High byte of oor
height 54
0–65535
0
Pulses
★

Table of Contents