6 Function Code Table NICE7000 User Manual
- 106 -
Function
Code
Parameter Name Setting Range Default
Unit
Property
Group F3: Running control parameters
F3-00
Startup speed 0.000–0.030
0.000
m/s
F3-01
Startup holding
time
0.000–0.500
0.15
s
F3-02
Acceleration rate 0.300–1.300
0.600
m/s2
F3-03
Acceleration start
jerk time
0.800–3.000
2.500
s
F3-04
Acceleration end
jerk time
0.800–3.000
2.500
s
F3-05
Deceleration rate 0.300–1.300
0.600
m/s2
F3-06
Deceleration end
jerk time
0.800–3.000
2.500
s
F3-07
Deceleration start
jerk time
0.800–3.000
2.500
s
F3-08
Special
deceleration rate
0.800–1.500
0.900
m/s2
F3-09
Pre-deceleration
distance
0–50.0
0.0
mm
F3-10
Re-leveling speed 0.040–0.080
0.040
m/s
F3-11
Inspection speed 0.080–0.630
0.250
m/s
F3-12
Low speed
emergency
evacuation speed
0.080 to F3-11
0.100
m/s
F3-13
Base oor
verication speed
0.100 to F0-04
0.500
m/s
F3-14
Emergency
evacuation function
selection
0–65535
32
-
F3-15
Normal speed
emergency
evacuation speed
0.080–0.500
0.080
m/s
F3-16
Acceleration rate
at emergency
evacuation
0.500–2.000
0.500
m/s2
F3-17
Normal speed
emergency
evacuation times
0–10
0
-
F3-18
Zero-speed control
time at startup
0.000–1.000
0.200
s
F3-19
Brake release
delay
0.000–1.5.000
0.600
s

Table of Contents