6 Function Code Table NICE7000 User Manual
- 110 -
Function
Code
Parameter Name Setting Range Default
Unit
Property
F5-29
X29 function
selection
0: Invalid
4: Safety circuit signal
5: Door lock circuit signal
4
-
F5-30
X30 function
selection
5
-
F5-31
X31 function
selection
5
-
F5-32
Y1 function
selection
0: Invalid
1: RUN contactor control
2: Brake contactor control
3: Shorting door lock circuit
contactor control
4: Fire emergency floor arrival
signal feedback
5: Door machine 1 open
6: Door machine 1 close
7: Door machine 2 open
8: Door machine 2 close
9: Brake and RUN contactors
healthy
10: Fault state
11: Running monitor
12: Shorting PMSM stator
contactor
13: Emergency evacuation
automatic switchover
14: System healthy
15: Emergency buzzer control
16: Higher-voltage startup
of brake
17: Elevator running in up
direction
18: Lamp/Fan running
19: Medical sterilization
20: Non-door zone stop
21: Electric lock
22: Non-service state
1
-
F5-33
Y2 function
selection
2
-
F5-34
Y3 function
selection
3
-
F5-35
Y4 function
selection
4
-
F5-36
Y5 function
selection
0
-
F5-37
Y6 function
selection
0
-
F5-38
Y7 function
selection
0
-
F5-39
Y8 function
selection
0
-
F5-40
Y9 function
selection
0
-
Group F6: Elevator logic parameters
F6-00
Top oor of the
elevator
F6-01 to 56
9
-