NICE7000 User Manual 6 Function Code Table
- 111 -
Function
Code
Parameter Name Setting Range Default
Unit
Property
F6-01
Bottom oor of the
elevator
1 to F6-00
1
-
F6-02
Parking oor F6-01 to F6-00
1
-
F6-03
Fire emergency
oor
F6-01 to F6-00
1
-
F6-04
Elevator lock oor F6-01 to F6-00
1
-
F6-05
Service oors 1 0–65535
65535
-
F6-06
Service oors 2 0–65535
65535
-
F6-07
Service oors 3 0–65535
65535
-
F6-08
Service oors 4 0–65535
65535
-
F6-09
Elevator function
selection 1
Bit0: Disability function
Bit1: Disabling returning to base
oor for verication
Bit2: Re-leveling function
Bit3: Door pre-open function
Bit4: Stuck hall call cancellation
Bit5: Peak service
Bit6: Down collective selective
peak service
Bit7: Fault auto reset
Bit8: Time-based service oor
function
Bit9: Disabling reverse oor
number clear
Bit10: Buzzer not tweet upon re-
leveling
Bit11: Car call deletion
Bit12: Hall call deletion
Bit13: Timed elevator lock
Bit14: Arrival gong disabled at
night
Bit15: Reserved
32768
-