NICE7000 User Manual 8 Troubleshooting
- 211 -
Fault
Code
Name Possible Causes Solution Level
Err19
Motor auto-
tuning fault
101, 102:
The motor auto-tuning
times out.
101, 102:
Enter the motor parameters
correctly.
Check the motor wiring and
whether phase loss occurs on the
contactor at the output side.
Check the encoder wiring and
ensure that the encoder PPR is
set properly.
Check whether the inspection
button is released before the
PMSM with-load auto-tuning is
nished.
5A
Err20
Speed
feedback
incorrect
1: AB signals are lost
during auto-tuning.
4: Z signal cannot be
detected during auto-
tuning.
5: The CD signal cables
of the SIN/COS encoder
break.
7: The UVW cables of
the UVW encoder break.
8: Reserved.
9: Overspeed occurs or
the speed deviation is
too large.
10/11: AB signals or CD
signals of the SIN/COS
encoder are interfered
with.
12: The detected speed
is 0 at torque limit.
13: AB signals are lost
during running.
14: Z signal is lost during
running.
19: The AB analog signal
cables break during low-
speed running.
55: CD signal error
or serious Z signal
interference occurs
during auto-tuning.
1 to 19:
Check that the setting of F1-
00, F1-12, and F1-25 for the
synchronous motor is correct.
Check that there is no mechanical
stuck.
Check that the brake has been
released during running.
55:
Check that the grounding is reliable
and eliminate interference problems.
5A

Table of Contents