6878215A01
Universal Relay Controller Installation O7/O9 Universal Relay Controller Cable Assembly 3-5
Figure 3-6.  Wire Installation with Black Stick
5. The lightbar gasket should be replaced at each reassembly of the wire.
NOTE: Use of other cable gages except as recommended in this manual may result in water 
intrusion. Any reassembly of wire needs a new lightbar gasket replaced. If the current loading 
for one wire is higher than 12 A, the wires should be splitted before being assembled to the 
URC system. Wires kit (PMKN4109_) is provided to ease installation of the URC. Incorrect 
use of the wires kit, e.g. improper connection at external loose end wires, may impact the 
robustness of the URC. 
 
Remove the wires and gasket residual inside the URC after the wire installation, before 
closing the top housing of the URC.
3.2.4 O7/O9 to URC Cable
The O7/O9 to URC cable (Motorola part number 3064153H02) can be assembled either before or 
after reassembling the top housing. Assemble the RJ45 port of the cable into the RJ45 connector on 
the URC and turn the locking collar instead of cable, 90 degrees to the right to ensure it is locked 
properly. After that, test whether the cable is locked properly or not by trying to pull out the cable.
Figure 3-7.  O7/O9 to URC Cable Installation