9.9 Troubleshooting
Problem Possible cause Solutions
Engine does not crank
Battery switch off Turn on battery switch.
Discharged battery, low battery voltage Check and charge the battery.
Blown fuse Check fuses. If the fuse blows again, find out
the cause. Contact service.
Battery cables poorly connected or
disconnected.
Check battery cables and posts, clean and
retighten if necessary.
Engine cranks but does not start, or
starts and stops immediately
No fuel or wrong type of fuel Drain the tank and fill the tank with correct
type of fuel. Drain water from the fuel filter.
Prime the fuel system.
Engine does not get fuel, clogged fuel
filter or fuel line.
Prime the fuel system.
Make sure that the fuel hoses and fuel filter
are clean and have not been frozen. Replace
fuel filter, clean fuel lines.
Cold temperature of the environment Hold ignition key in glow position for longer.
If glow indicator lamp is lit, allow it to turn off
before starting. Switch on the engine for at
least 5 seconds.
Battery discharged or damaged Charge the battery or replace if damaged.
Engine overheats
Overload Use attachment at lower engine rpm, check
attachment for faults.
Hydraulic system overheats
Clogged oil cooler. Clean cooler and fan.
Fan faulty Check and clean, repair if necessary.
Hydraulic system overloaded Use attachment at lower engine rpm, check
attachment for faults.
The loader does not move even after the
parking brake has been released
Bad connection on the wiring of the parking
brake switch, blown fuse, or faulty switch.
Check wires, fuse, and switch, repair if
necessary. Contact service.
Low hydraulic charge pressure. Contact service for pressure check.
TAB. 23