Troubleshooting
Faults without diagnostic message
110 10.06.2014
Symptom Cause Solution
The sealing force is not suffi-
cient.
Without the inert gas option:
check settings. Sufficient seal-
ing force is only achieved if
the target pressure target
value is set under 400 mbar.
Inert gas option: Increase the
pressure on the gas cylinder,
and then gradually increase
the sealing force on the seal-
ing pressure regulator.
Sealing bar damaged. Replace sealing bar.
The set pressure target value
is not achieved (e.g. product
contains water).
Set a higher pressure target
value.
Chamber lid gasket is dirty. Clean the chamber lid gasket.
Insufficient oil quantity or oil in
the vacuum pump is too old.
Fill or replace oil.
Chamber lid gasket is dam-
aged.
Notify MULTIVAC Service.
Pressure target value is
not reached.
Evacuation system is leaking. Notify MULTIVAC Service.
Air de-oiling element is defec-
tive.
Change air de-oiling element. Odour or smoke.
Oil return valve of vacuum
pump is blocked.
Notify MULTIVAC Service.