Troubleshooting
Faults with diagnostic message
10.06.2014 109
Symptom Cause Solution
Vacuum pump was not trig-
gered, overload current relay
has signalled or vacuum pump
is defective.
Notify MULTIVAC Service.
Vacuum pump is leaky. Notify MULTIVAC Service.
Filter in the line to the vacuum
sensor is dirty and blocked.
Notify MULTIVAC Service.
Leak in hose connections. Notify MULTIVAC Service.
Leak in vacuum hose. Notify MULTIVAC Service.
80
The vacuum sensor and as-
sociated line is leaking.
Notify MULTIVAC Service.
81 Sealing diaphragm leaks. Notify MULTIVAC Service.
8.2 Faults without diagnostic message
Symptom Cause Solution
Machine is switched off. Switch on the machine. Machine does not run.
Mains plug is unplugged. Plug in the mains plug.
Chamber lid pressed closed
too briefly.
Press chamber lid closed
more firmly and for longer.
Chamber lid gasket is dirty. Clean the chamber lid gasket.
Chamber lid does not
remain closed despite
pump running.
Chamber lid gasket is dam-
aged.
Notify MULTIVAC Service.
• The time Fill diaphragm is set
too low.
Correct the time Fill dia-
phragm.
Sealing time is incorrectly set. Correct Sealing time.
Sealing pressure is incorrectly
set.
Correcting the sealing pres-
sure.
Pouch neck is clamped by
chamber lid.
Insert the film pouch so that
the pouch neck lies within the
chamber.
Seal seam is dirty. Keep sealing bar and film
pouch clean.
Pack not air-tight. Use a new film pouch.
Seal seam not airtight -
pack is slack.
Film pouch not suitable. Use a film pouch suitable for
sealing.