Maintenance
Maintenance recommendation
96 10.06.2014
7.2.15 Vacuum pump type MRP60 - Oil change
¾ Change the oil in the vacuum pump,.
7.2.16 Vacuum pump type MRP60 - Exchanging the air de-
oiling element
¾ Change the air de-oiling element, see Section 7.4 "CHANGE THE
AIR DE-OILING ELEMENT MRP60".
7.2.17 Vacuum pump type R5-RAxxx - Changing the oil
and oil filter
¾ Have MULTIVAC Service change the oil and oil filter.
7.2.18 Vacuum pump type R5-RAxxx - Exchanging the air
de-oiling element
¾ Have the air de-oiling element changed by the MULTIVAC service
department.
7.2.19 Vacuum sensor - Exchanging the filter
¾ Exchanging the vacuum sensor filter, see Section 7.6 "EXCHANG-
ING THE VACUUM SENSOR FILTER".
7.2.20 Basic setting - Checking, adjusting
¾ For the gas flushing option: Check the operating pressure for seal-
ing and adjust if necessary, see Section 5 "ADJUSTMENT WORK
AND SETUP ".
¾ Check input pressure of inert gas (option), adjust if necessary, see
"Technical specifications".
7.2.21 Vacuum system - Check
¾ Perform a vacuum test, see Section 7.5 "PERFORMING THE VAC-
UUM TEST".
7.2.22 Vacuum filter (option) - Change
¾ Switch off the machine.