Cleaning
Notes on cleaning
10.06.2014 71
NOTICE Danger of material damage!
Acidic cleansers are caustic.
These can cause plastics to become brittle and age prematurely.
¾ Do NOT shorten the cleaning intervals for acidic cleaning and
disinfection.
NOTICE Danger of material damage!
Inappropriate work on anodized aluminium parts causes a damag-
ing of the anodized coating.
This will lead to aluminium corrosion.
¾ Do not use metal scraping tools.
¾ Do not use harsh cleansers.
¾ Do not use cleaning devices with abrasive surface.
¾ Residues of cleansers and other aggressive deposits must be
removed immediately.
Regular and correct maintenance prolongs the life of the unit. The
best protection against harmful influences is to clean and disinfect the
machine on a regular basis. The longer product residue and other
aggressive deposits remain on the unit, the more harmful their corro-
sive effects will be.
If used incorrectly, care products can damage components made of
rubber or plastic. Before applying care products, please take time to
read the notes and warnings provided by the manufacturer.
6.1.4 Parameters for pre-rinsing and after-rinsing water
Low pressure of max. 4 bar to 6 bar (58 psi to 88 psi).
Do not rinse with steam jets or high-pressure cleaners.
Fan nozzle: 5 ° to 15 ° inclination, approx. 3/16 '' nozzle opening.
Temperature: max. 60 °C (140 °F).
Quality of after-rinsing water: drinking water quality.
6.1.5 Handling cleansers
WARNING
Chemical burn hazard!
Cleansers are caustic. Caustic effects are NOT noticed immedi-
ately.
Contact with the skin can cause burns.
¾ Wear the prescribed personal protective equipment when han-
dling cleansers.
¾ Observe the manufacturer's instructions.