Operation
Working with recipes
10.06.2014 61
¾ Call up "Recipe, deleting" menu.
¾ Select the recipe to be deleted with the <arrow> keys.
¾ Press the <Function selection> key.
The message “completed” appears.
The recipe has been deleted.
4.9 Select and set process
4.9.1 Set standard process
¾ Press <Evacuation> key briefly and enter value for Evacuation
pressure.
¾ For automatic evacuation, decrease the value until Automatic
appears.
The machine controls the evacuation process automatically.
¾ Press <Evacuation> key briefly again and set value for Post-
evacuation time.
¾ Call up the "evacuation" menu.
¾ Set Distribution time.
¾ Set Automatic.
¾ Select Standard process.
¾ Call up the "gas flushing" menu (Optional).
¾ Switch on On/off gas flushing.
¾ Set Distribution time.
¾ Set Rinse time.
¾ Press <Gas flushing> key briefly and set value for Gas flushing
pressure.
4.9.2 To set MCV process
¾ Press <Evacuation> key briefly and enter value for Evacuation
pressure.
Info
Do not set an Evacuation pressure value in Automatic.
¾ Press <Evacuation> key briefly again and set the value for Post-
evacuation time to 0 s.
¾ Call up the "evacuation" menu.
¾ Set the value for Distribution time to 0 s.