EasyManua.ls Logo

multivac C300 - Operation; Machine Power On;Off; Packing Products

multivac C300
140 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
54 10.06.2014
4 Operation
4.1 Switching on the machine
¾ Open all stop valves in the supply lines.
¾ If available, switch on the main switch.
¾ Switch on the display with the <control on/off> key.
The machine control performs a self-test.
The software version of the machine control briefly appears in
the display.
The status display appears.
The machine is ready for operation.
4.2 Switching off the machine
¾ Switch off the display with the <control on/off> key.
¾ Turn off the main switch, if one is present.
¾ Close all stop valves in the supply lines.
¾ Close chamber lid and lock it in place.
¾ If required disconnect the machine from the mains electricity.
4.3 Packing products
¾ Switch on the machine.
¾ Load the desired recipe.
¾ For the first test packs, use a preset recipe, see Section 2.8
"PRESET RECIPES " and see Section 4.8.2 "LOAD FACTORY SET-
TINGS ".
WARNING
Health hazard!
Insufficient or sporadic cleaning can promote the growth of micro-
organisms which can contaminate the product.
This can pose serious health hazards for consumers.
¾ Disinfect your hands should they come into contact with any
machine part other than the operating elements.
¾ Do NOT lay the product on the machine.
¾ Observe the company cleaning guidelines.
¾ Follow instructions in the chapter 'Cleaning'.