4.15 Reset machine control
Info
Reset machine control in the following situations:
Creating the condition as supplied to the customer of the ma-
chine.
If the configuration code was incorrectly entered.
Delete the entire memory.
The machine control unit no longer responds.
¾ Displaying the configuration code.
¾ Switch off the display with the <Machine control on/off> key.
¾ Switch on the display with the <Machine control on/off> key.
¾ Read off the set configuration code during the startup display
and make a note of it.
¾ While the startup display is shown, press the keys <2> and <5>
simultaneously.
¾ Enter Super-PIN, see supplementary sheet "Super-PIN".
The "Reset" display appears.
A counter counts to zero.
The display automatically switches off and back on again.
The password for the access right Set-up personnel remains
activated.
The "Configuration code" display appears.
¾ Compare the suggested configuration code in the display with the
noted configuration code.
¾ If the configuration codes match, press the <Sealing> key
The configuration code is saved.
¾ If the configuration codes differ, enter the noted configuration
code.
¾ Press the <Evacuation> key.
The suggested configuration code is deleted.
¾ Enter the noted configuration code with the keys <1> to <6>.
¾ Press the <Sealing> key.
The configuration code is saved.
¾ Switch off the display with the <Machine control on/off> key.
¾ Switch on the display with the <Machine control on/off> key.
Factory settings are loaded.