Operation
Reset machine control
66 10.06.2014
4.15 Reset machine control
Info
Reset machine control in the following situations:
• Creating the condition as supplied to the customer of the ma-
chine.
• If the configuration code was incorrectly entered.
• Delete the entire memory.
• The machine control unit no longer responds.
¾ Displaying the configuration code.
¾ Switch off the display with the <Machine control on/off> key.
¾ Switch on the display with the <Machine control on/off> key.
¾ Read off the set configuration code during the startup display
and make a note of it.
¾ While the startup display is shown, press the keys <2> and <5>
simultaneously.
¾ Enter Super-PIN, see supplementary sheet "Super-PIN".
– The "Reset" display appears.
– A counter counts to zero.
– The display automatically switches off and back on again.
– The password for the access right Set-up personnel remains
activated.
– The "Configuration code" display appears.
¾ Compare the suggested configuration code in the display with the
noted configuration code.
¾ If the configuration codes match, press the <Sealing> key
– The configuration code is saved.
¾ If the configuration codes differ, enter the noted configuration
code.
¾ Press the <Evacuation> key.
– The suggested configuration code is deleted.
¾ Enter the noted configuration code with the keys <1> to <6>.
¾ Press the <Sealing> key.
– The configuration code is saved.
¾ Switch off the display with the <Machine control on/off> key.
¾ Switch on the display with the <Machine control on/off> key.
– Factory settings are loaded.
– The status display appears.