Operation
Select and set process
10.06.2014 63
¾ Select the desired function with the <Gas flushing> key and the
<Arrow> keys.
¾ Set the value with the <Sealing> key and the <Arrow> keys.
¾ Scroll through the list using the <Evacuation> key and the <Ar-
row> keys.
4.9.5 Set MRP process
¾ Press <Evacuation> key briefly and enter value for Evacuation
pressure.
¾ For automatic evacuation, decrease the value until Automatic
appears.
The machine controls the evacuation process automatically.
¾ Press <Evacuation> key briefly again and set value for Post-
evacuation time.
¾ Call up the "evacuation" menu.
¾ Set Distribution time.
¾ Set Automatic.
¾ Select MRP process.
¾ Set Number of cycles.
¾ Set Cycle end.
¾ Call up the "gas flushing" menu (Optional).
¾ Switch on On/off gas flushing.
¾ Set Distribution time.
¾ Set Rinse time.
¾ Press <Gas flushing> key briefly and set value for Gas flushing
pressure.
4.10 Setting the sealing
¾ Call up the "settings" menu.
¾ Call up the "sealing" menu.
¾ Switch on On/off sealing.
¾ Set Delayed ventilation.
¾ Set Cooling down.
¾ Set Ventilation pulse.
¾ Press the <Sealing> key briefly and set the value for the first seal-
ing time.