Cleaning
Notes on cleaning
10.06.2014 73
6.1.7 Corrosion protection and lubrication
WARNING
Health hazard!
Excess lubricants can accumulate at lubrication points.
Excess grease has no lubricating function; however, it can breed
micro-organisms and contaminate the product.
¾ Check the lubricating points regularly for the accumulation of
excess lubricants.
¾ Remove any excess lubricants.
NOTICE Danger of material damage!
Residues of cleansers and disinfectants produce corrosion.
Corrosion can destroy the machine.
¾ After every cleaning, including cleaning of the surroundings
(floor, adjacent machines, etc.), thoroughly rinse with water of
drinking water quality or clean by hand.
Kind of anti-corrosion agent, refer to "Care products table".
Only use H1 or FDA-approved lubricants and anti-corrosion agents.
Checking the microbiological stability of the anti-corrosion agent
and lubricants regularly helps reduce the risk of product contami-
nation.
6.1.8 Cleaning devices
Wet cleaning
WARNING
Health hazard!
The cleaning devices will become germ hot spots if they are not
cleaned often enough.
This can cause cross contamination, which will damage the prod-
uct.
¾ Use only plastic brushes and brooms.
¾ Clean the cleaning devices daily and apply disinfectant after-
wards.
Dry cleaning
The exhaust air emitted by the vacuum cleaner and whirled up must
comply with the prescribed limit values for the packaging environment.
Accordingly, the appropriate filter elements must be used in the vac-
uum cleaner.