Maintenance
10.06.2014 91
7 Maintenance
DANGER
Dangerous voltage!
Switching off the machine does not rid it of electrical current.
Touching electrically charged components can cause serious or
even fatal injuries.
Before performing any cleaning or service work:
¾ Disconnect the machine's power supply from the mains electric-
ity.
¾ Have work in the control cabinet performed by authorised tech-
nicians only.
Info
Observe the safety instructions, see Section 1 "S
AFETY".
Clean the machine after maintenance work and repairs and disin-
fect if necessary.
7.1 Maintenance schedule
As needed
Page Complet
ed
Entire machine Perform intermediate disinfection
93
Entire machine Perform a wipe test
93
Vacuum sensor Exchanging the filter
96
Vacuum filter (option) Change
96
Every 8 operating hours or daily
Page Complet
ed
Entire machine Visual inspection
92
Entire machine Alkaline cleaning and disinfection
93
Entire machine Intensive cleaning
93
Chamber lid viewing
window
Visual inspection
93
Chamber lid gasket Visual inspection
93
Sealing bars Visual inspection
94
Internal vacuum pump Checking oil level, topping up
94