10.06.2014 127
MHP
p (mbar)
t (s)
V1
0
t1
t2
Fig. 54: Example diagram of MHP
t1
Evacuation pause
t2
Evacuation time
V1
Evacuation pressure
During the MHP process, evacuation takes place in several steps.
The air is suctioned out for a set time (evacuation time); a set pause
in suctioning (evacuation pause) follows. Afterwards, the air is fur-
ther evacuated. The steps are repeated.
MHP evacuation pause
[Parameter of the control unit]
Defines the duration of the intervals between two evacuation pulses
during the MHP process.
MHP evacuation time
[Parameter of the control unit]
Defines the duration of the evacuation pulses during the MHP proc-
ess.