EasyManua.ls Logo

multivac C300 - Page 129

multivac C300
140 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Glossary
10.06.2014 129
MRP
[Optional]
P3
P2
P1
t
P
12
Fig. 56: Example diagram of MRP (cycle end: gas flushing)
1
Cycle 1
2
Cycle 2
P1
Evacuation pressure
P2
Gas flushing pressure
P3
Ambient pressure
P3
P2
P1
t
P
12
Fig. 57: Example diagram of MRP (cycle end: evacuation)
1
Cycle 1
2
Cycle 2
P1
Evacuation pressure
P2
Gas flushing pressure
P3
Ambient pressure
During the MRP (MULTIVAC Repeated Processing) process,
evacuation and gas flushing takes place alternately over several
cycles. The machine evacuates and flushes gas to the set pressures
and repeats the procedure according to the settings.
Number of cycles
[Optional] [Parameter of the control unit]
Defines how many cycles are to be completed in the MRP process.
A cycle is comprised of evacuation and gas flushing. The residual
oxygen content is reduced by the repeated evacuation and gas
flushing.

Table of Contents