Section 75 00-02-0878
2013-03-07 - 118 -
Displaying Alarms - EMS-GC10
J1939
Use the up and buttons until the DM1 or DM2 is shown in the display and press Enter.
The alarm log will be shown in the display.
Example:
DM1 LOG DDEC
Oil pressure
Low level warning
SPN 100
FMI 17
The alarm log in DM1 shows the active alarms, the DM2 shows the historical alarms.
Use the up and down buttons to scroll through the list.
Scania KWP 2000
Use the up or down button until the engine log is shown in the display and press enter.
The alarm log will be shown in the display.
Example:
Scania KW2000 LOG
1105 Speed sensor 1
Active alarms: 6
The Scania KWP 2000 log shows active and passive alarms in a mix.