2.2 Troubleshooting with Error Messages VJ1324E-M-02
2.2.3 Errors Requiring Reboot P.2-30
20 E090 Err
Heater Volt.
Displayed when
voltage exceeds
the threshold
level of 200V
start up even
though the printer
was started with
the voltage of
100V on
HEATER CONT
board Assy .
Input voltage from AC inlet or HEATER CONTROL board
Assy may be malfunctioning.
1. Connect two power cables(for MAIN and for
HEATER) to separate outlets.
2. Check the connection of HEATER CONT board
Assy.
3. Replace HEATER CONT board Assy .
"3.4.7 Replacing HEATER
CONT Board Assy" p.3-46
21 E093 Err
Control Ver
Controller F/W
may be
malfunction.
1. Controller F/W version may be malfunction.
2. HEATER CONT board Assy may be malfunction.
1. Replace HEATER CONT board Assy. "3.4.7 Replacing HEATER
CONT Board Assy" p.3-46
22 E097 Err
NVRAM.
An anomaly is
detected in
NVRAM.
MAIN board Assy may be malfunctioning. Replace MAIN board Assy . "3.4.4 Replacing MAIN Board
Assy" p.3-42
23 E140Err
Pre heat Th.
An anomaly is
detected in Pre
Tthermistor.
1. Thermistor connector may be malfunctioning.
2. Thermistor may be disconnecting.
3. HEATER CONT board Assy may be malfunctioning.
1. Make sure to connect thermistor connector
securely.
2. Repace Themistor.
3. Replace HEATER CONT board Assy.
"3.4.7 Replacing HEATER
CONT Board Assy" p.3-
46 "3.5.6 Replacing Heater
Section" p.3-71
24 E141Err
Platen heat Th.
An anomaly is
detected in Platen
Tthermistor.
25 E142Err
After heat Th.
An anomaly is
detected in After
Tthermistor.
No. Message Symptoms Check Item Action Reference