Technical Data
2 - 3
9.612.0.006.7160 - 05/04
Thermostat
Lubrication System
Description
Oil pressure
Nominal speed
Idling speed
4.5 bar (hot engine)
1.0 bar (hot engine)
Oil temperature
Nominal
Maximum
90 - 110 °C
120 °C
Oil capacity
• Minimum
Maximum (without filter)
Maximum (with filter)
Description
Volume of water in the
engine, without radiator
Water temperature
Nominal
Maximum
Cooling System
4.12TCE 6.12TCE
5 l
8 l
9,2 l
4.12TCE 6.12TCE
80 - 90 °C
100 °C
13 l
17 l
18,7 l
7 l 9 l
Variation pressure of the
filter to open by-pass
2,5
+ 1,2 bar
- 0,3 bar
Opening beginning Total opening
17.210E OD
Thermostat
9.412.0.757.001.6 75 ± 2°C 90°C
Minimum operation course
10.0 mm
Opening beginning Total opening
9.150E / 17.260E OT
Thermostat
9.412.0.757.002.6 80 ± 2°C 95°C
Minimum operation course
10.0 mm
13 l
17 l
18,2 l
17 l
29 l
30,2 l
23 l
32 l
33,7 l