Receiver extra settings
Set/Request Packet D7h
Packet D7h requests or sets the following additional operation parameters:
a) PVT solution rate;
b) 1PPS control;
c) signal delay in antenna cable;
d) operation mode;
e) SNS priority
PVT solution rate
The host provides repeated PVT solution update 1Hz (default), 2Hz or 5Hz rate. To set the solution
processing rate to 5Hz, packet D7h must have following structure:
1
-data type: PVT solution rate
Data type format - INT8U
2
- PVT solution rate: 1, 2, 5 Hz
Data type format - INT8U