5. Steps to upgrade to 4K
175
Error code Error message Description
257 Fan7 Stop Precaution Fan7 Stop Precaution (NC3200 Series)
258 Fan8 Stop Precaution Fan8 Stop Precaution (NC3200 Series)
259 Fan9 Stop Precaution Fan9 Stop Precaution (NC3200 Series)
260 Lamp Fan0 Stop Precaution Lamp Fan0 Stop Precaution
261 Lamp Fan1 Stop Precaution Lamp Fan1 Stop Precaution
262 Pump Stop Precaution Pump Stop Precaution
263 ICP Fan Stop Precaution ICP Fan Stop Precaution
265 Fan11 Stop Precaution Fan11 Stop Precaution. (NC3240)
270 SD Tamper Terminate Terminated service door tamper event
latched by Enigma board.
* This message would be shown on Log,
not on LCD.
271 IMB:SD Tamper Terminate Terminated service door tamper event
latched by IMB.
* This message would be shown on Log,
not on LCD.
280 Bulb Warranty Over Bulb warranty time over.
301 System Error ICP board error
302 Self Test Error ICP board error
To recover the issue, update ICP to higher
than Prod3.0 or equal. If that can not
remove the issue, remove and reseat the
ICP board.
303 Install Release Package Error ICP board error
It could be caused by disk space issue or
DISKCHIP corruption issue.
304 Load Release Package Error ICP board error
It could be caused by disk space issue or
DISKCHIP corruption issue.
305 Key Error ICP board error
306 Certificate Error ICP board error
317 ICP Normal Configuration Error ICP board error
318 ICP Boot Configuration Error ICP board error
319 FMT Normal Configuration Error ICP board error
320 FMT Boot Configuration Error ICP board error
321 FMT Satellite Configuration Error ICP board error
322 1.20V Supply out of range ICP board error
323 1.80V Supply out of range ICP board error
324 2.50V Supply out of range ICP board error
325 3.30V Regulator out of range ICP board error
326 ICP FPGA Temperature out of range ICP board error
327 FMT FPGA Temperature out of range ICP board error
328 ICP Flash Update Error ICP board error
329 FMT Sequence Data File Mismatch ICP board error
330 FMT DMD Data File Mismatch ICP board error
331 FMT Flash Checksum Error - Sequence Data
ICP board error
332 FMT Flash Checksum Error - DMD Data ICP board error
333 Satellite Hardware Mismatch ICP board error
334 FMT Flash Update Error ICP board error
335 Red Satellite Reports Reset ICP board error
336 Red Satellite Serial Link Error ICP board error