Error code Error message Description
434 TLS Integrity Error Enigma is in FIPS error state. (Integrity
check error)
435 FPGA Configuration Integrity Error Enigma is in FIPS error state. (Integrity
check error)
436 FPGA CineLink 2 Decryption Integrity Error Enigma is in FIPS error state. (Integrity
check error)
437 RTC Error Indicates that Enigma RTC is set to a date
before January 1, 2009, and is likely
invalid. If the year value is less than 2009,
then the time is considered to be "invalid"
442 FPGA Configuration Error Enigma Status error
443 FPGA Temperature out of range Enigma Status error
446 RNG Hardware Duplicate Output Error Enigma is in FIPS error state. (Integrity
check error)
447 DRNG Algorithm Duplicate Output Error Enigma is in FIPS error state. (Integrity
check error)
450 1.20V Supply out of range Enigma Status error
451 1.80V Supply out of range Enigma Status error
452 2.50V Supply out of range Enigma Status error
453 3.30V Regulator out of range Enigma Status error
458 SelfTest User Loader Integrity Error Enigma is in FIPS error state. (Self test
result)
459 SelfTest Main Application Integrity Error Enigma is in FIPS error state. (Self test
result)
460 SelfTest RNG Hardware Integrity Error Enigma is in FIPS error state. (Self test
result)
461 SelfTest DRNG Algorithm Integrity Error Enigma is in FIPS error state. (Self test
result)
462 SelfTest RSA Algorithm Integrity Error Enigma is in FIPS error state. (Self test
result)
463 SelfTest AES Algorithm Integrity Error Enigma is in FIPS error state. (Self test
result)
464 SelfTest HMAC Algorithm Integrity Error Enigma is in FIPS error state. (Self test
result)
465 SelfTest SHA Algorithm Integrity Error Enigma is in FIPS error state. (Self test
result)
466 SelfTest TLS Integrity Error Enigma is in FIPS error state. (Self test
result)
467 SelfTest FPGA Configuration Integrity Error Enigma is in FIPS error state. (Self test
result)
468 SelfTest FPGA CineLink. 2 Decryption
Integrity Error
Enigma is in FIPS error state. (Self test
result)
474 Security Tamper Security tamper condition exists in
Enigma.
475 Top Side Security Enclosure Open Security tamper condition exists in
Enigma.
476 Bottom Side Security Enclosure Open Security tamper condition exists in
Enigma.
477 Security Battery Event Battery tamper condition exists in Enigma.
478 Software Commanded Zeroization Destroyed Enigma key by software
command.