CHAPTER 3 SYSTEM DATA PROGRAMMING
– 119 –
NWA-008855-001 Rev.1.0
avch3001.fm
PS DATA PROGRAMMING
PS Data Programming
(1) PS Data Programming via Data Set Adapter
Using the Data Set Adapter, the following data can be written onto each PS.
System ID (SYS-ID) : CS ID for controlling the whole PHS system, enabling both the CS and PS to
correspond
Individual PS No. : Maximum number of 8 digits used in the Home Office and this number is for
convenience usually the same as the station number
PS Station No. : Numbers when dialed to make a call. Maximum 8 digits are available and
these numbers can be displayed on the LCD.
Transceiver ID : Numbers used in dialing in the transceiver mode and these are usually identi-
cal to the station number
The data is loaded to the floppy disk, with file names attached. These files are such that they are com-
piled and different PS-IDs are allocated to different PSs. These files include the above parameters.
NOTE: When using the Data Set Adapter, System ID is to be entered, so you have to know in advance
the System-ID that each Control CS has. The System ID of the Control CS is written on the back
of the CS.
(2) Downloading of Assigned Data
Download the PS data to the PBX from the MAT.
PC
PS PS
(PS-ID)
Downloaded by the Data
Set Adapter
MAT
(PC)
Control CS
Download
from MAT
(System ID)
PBX
Data Set Adapter
FD
CSI
CS
PS DATA PROGRAMMING