CHAPTER 3 SYSTEM DATA PROGRAMMING
– 88 –
NWA-008855-001 Rev.1.0
avch3001.fm
Office Data Conversion
When upgrading the software of the system from Series 3300 or before to Series 3400 or later, the office
data conversion by CM00>90 is required. The office data that has been converted and the office data in
Series 3400 software or later are incompatible with the software of Series 3300 or before. We recommend
to execute the system data backup before the office data conversion.
NOTE: When upgrading the software in Retrofit system to Series 3400 or later, convert the office data
using “Office Data Converter” in the MATWorX CD-ROM and then execute the office data
conversion by CM00>90.
DESCRIPTION DATA
Execute the office data conversion.
[Series 3200 R6.2 software required]
(1)
(2)
90
0: Start conversion
1: Always displayed after first data “90” is
typed NOTE 1
NOTE 1: When first data “90” is typed, second data “1” is displayed. Also while converting the
office data, “1” is displayed.
NOTE 2: There is no problem even if the office data conversion is executed repeatedly.
START
CM00
OFF LINE
END
PRECAUTIONS