CHAPTER 3 SYSTEM DATA PROGRAMMING
– 153 –
NWA-008855-001 Rev.1.0
avch3001.fm
Station Hunting-Not Available
DESCRIPTION DATA
Provide the Station Hunting-Not Available
when the called PS is out of cell or the power
is off.
(1)
(2)
510
0: Available
Specify whether the RBT is sent when the
called PS is out of cell or the power is off.
NOTE: CM08>503 is effective only for Sta-
tion-to-Station call.
(1)
(2)
503
0: Not sent
1: To send
Assign the station numbers included in the sta-
tion hunting group, one by one, as shown be-
low.
Station Hunting-Terminal
1st Operation : (1) Station A (2) Station B
2nd Operation: (1) Station B (2) Station C
Station Hunting-Circular
1st Operation : (1) Station A (2) Station B
2nd Operation: (1) Station B (2) Station C
3rd Operation : (1) Station C (2) Station A
•
(1)
(2)
Y=0
X-XXXXXXXX: Virtual Station No. as-
signed by CM14
X-XXXXXXXX: Virtual Station No. as-
signed by CM14
Specify the kind of station included in the sta-
tion hunting group.
•
(1)
(2)
Y=1
X-XXXXXXXX: Virtual Station No. as-
signed by CM14
0 : Member station of Station Hunting-
Terminal
1 : Pilot station of Station Hunting-Ter-
minal
All stations of Station Hunting-Circu-
lar
Specify the message reply timer for An-
nouncement-PS Out of Cell/PS Power Off.
•
(1)
(2)
Y=0
85
01-99: 4-396 seconds
(4 second increments)
If no data is set, the default setting is 8-12 sec-
onds.
START
CM08
CM18
CM41
END
WCS FEATURE PROGRAMMING