PS Location Indication
ND-91638-007(E) Page 29
Issue 6
PS Location Indication
General Description
When a PS calls a D
term
/Attendant Console or vice versa, this feature allows to indicate the location name of
the Cell Station (CS) that is connected to the PS on the LCD of the D
term
.
Configuration Application
Integrated Type
Operating Procedure
No manual operation is required.
Service Conditions
1. This feature is available, regardless of a Nation Code and system configuration such as the number of ports
or PIMs.
2. SPN-SC03B 8CSH-A (AP) can be used as CSH.
3. The CS Name is displayed on the LCD of a D
term
and Attendant Console. And it is not changed by Nation
Code.
4. When the D
term
or Attendant Console user makes/receives a call to/from a PS, CS Name of which the PS is
connected is displayed on the LCD of the D
term
if the CS Name is assigned by system programming.
a. When the CS name is not assigned in the system, the display on the LCD is the same as a normal call.
b. CS Number is not displayed.
5. Conditions to display the CS Name are as follows.
a. To display on the LCD of a D
term
1) Station Data 1 (CM12 YY=02; Service Class of a virtual LC assigned by CM10) and Service Restric-
tion Class (CM15 YYY=148, 2nd data; PS Location Indication) must be assigned to “allow” this fea-
ture for desired PSs.
2) Station Data 1 (CM12 YY=02) and Service Restriction Class (CM15 YYY=149, 2nd data; PS Loca-
tion Indication) must be assigned to “allow” this feature for desired D
term
s.
* The CS Name is not displayed on the LCD of the D
term
when the data of the D
term
/PS is assigned to
“restrict” at Item 1) or 2), and only the PS number or PS number with name is displayed.
b. To display on an Attendant Console
1) Station Data 1 (CM12 YY=02; Service Class of a virtual LC assigned by CM10) and Service Restric-
tion Class (CM15 YYY=148, 2nd data; PS Location Indication) must be assigned to “allow” this fea-
ture for desired PSs.
2) CM08 1
st
= 521 (PS Location Indication on Attendant Console) must be assigned to “allow” this fea-
ture.
* The CS Name is not displayed on the LCD of the Attendant Console when the data of the Attendant
Console/PS is assigned to “restrict” at Item b-1 and b-2, and only the PS number or PS number with
name is displayed.