CHAPTER 2 INSTALLATION
– 39 –
NWA-008855-001 Rev.1.0
avch2001.fm
REQUIRED EQUIPMENT
The table below shows the equipment required to provide the WCS interface to the system.
WCS Required Equipment
EQUIPMENT DESCRIPTION QUANTITY REMARKS
• WCS with Legacy CS
PZ-PW122
(DC/DC PWR)
Power supply card for CS 1-8 One per PIM
16 CSs powered/card
PWR CNT CA-D Power Control Cable-D (between
PW121/PW122 and BWB)
1-7 For PIM1-7
PWR CNT CA-E Power Control Cable-E (between
PW121/PW122 and BWB)
1 For PIM0
PN-2CSIA-A (CSI) CS Interface card for S-interface 1-64 8 per PIM
PN-2CSIH (CSI) CS Interface card for U-interface 1-64 8 per PIM
PN-4CSIA (CSI) CS Interface card for U-interface 1-32 4 per PIM
PN-SC03-B (CSH) CS Handler card for S-interface/U-
interface
1-16 PN-2CSIA-A/PN-
2CSIH: 4 CSI/card
PN-4CSIA: 2 CSI/card
PN-CFTB 6/10 Party Conference Trunk N N: As required for
Group Call
PN-4DATC Digital Announcement Trunk N N: As required for
Announcement
Service
PN-2COT
PN-4COT
PN-6COT
PN-8COT
Central Office Trunk N For Adjunct Type
(Analog Interface)
N: 2 PS/2-line COT
N: 4 PS/4-line COT
N: 6 PS/6-line COT
N: 8 PS/8-line COT
PN-24DTA-C (DTI) 24-channel DTI card 1-8 For Adjunct Type
(CCIS Interface)
PN-30DTC-C (DTI) 30-channel DTI card 1-8
PN-SC00 (CCH) Common Channel Handler card 1-8
Continued on next page
REQUIRED EQUIPMENT