Loading...
CHAPTER 3 SYSTEM DATA PROGRAMMING
– 123 –
NWA-008855-001 Rev.1.0
avch3001.fm
TRUNK DATA PROGRAMMING (For Adjunct Analog)
This programming is required for Adjunct Type (Analog Interface).
DESCRIPTION DATA
Assign the sending Switch Hook Flash for Ad-
junct Analog system.
(1)
(2)
525
0: To send
Assign a trunk number to the required LEN. (1)
(2)
XX ZZZ (LEN)
XX : 00-59: FP No.
ZZZ: 000-127: Port No.
D000-D255: Trunk No.
Assign the trunk route number to the trunk
number.
(1)
(2)
Y=00 DP or DTMF
000-255: Trunk No.
00-63: Trunk Route No.
Assign the data for terminating system.
(1)
(2)
Y=02 Day Mode
Y=03 Night Mode
Y=40 Mode A
Y=41 Mode B
000-255: Trunk No.
04: Direct-In Termination
Assign the Virtual station number to be termi-
nated by Direct-In Termination.
(1)
(2)
Y=04 Day Mode
Y=05 Night Mode
Y=42 Mode A
Y=43 Mode B
000-255: Trunk No.
X-XXXXXXXX: Virtual Station No. as-
signed by CM14
Assign the kind of trunk to the trunk route.
(1)
(2)
Y=00
00-63: Trunk Route No.
00: C.O. Trunk
Specify the dialing signal type to the trunk
route.
(1)
(2)
Y=01
00-63: Trunk Route No.
4: Call Origination-DTMF
Call Termination-DTMF
START
CM08
CM14
CM30
CM35
A
TRUNK DATA PROGRAMMING (For Adjunct Analog)

Table of Contents