CHAPTER 3 SYSTEM DATA PROGRAMMING
– 124 –
NWA-008855-001 Rev.1.0
avch3001.fm
DESCRIPTION DATA
Assign the call direction to the trunk route. •
(1)
(2)
Y=02
00-63: Trunk Route No.
3 : Bothway Trunk
Specify the answer signal from the distant of-
fice for outgoing connection to the trunk route.
•
(1)
(2)
Y=04
00-63: Trunk Route No.
1: Battery Reversal
Specify the release signal from the distant of-
fice for an outgoing connection of an incoming
connection to the trunk route.
NOTE: In case of Adjunct Type (Analog In-
terface), using a line card over the
Main PBX is recommended to pro-
vide the release signal (i.e., momen-
tarily, an open circuit).
•
(1)
(2)
Y=05
00-63: Trunk Route No.
1 : Release signal arrives
Assign the sending of the dial pulse on an out-
going call to the trunk route.
•
(1)
(2)
Y=08
00-63: Trunk Route No.
3 : Dial pulses are sent out
Assign the incoming connection signaling to
the trunk route.
•
(1)
(2)
Y=09
00-63: Trunk Route No.
15 : Ring Down (Loop Start C.O.)
Assign the sending Switch Hook Flash for Ad-
junct Analog System.
•
(1)
(2)
Y=169
00-63: Trunk Route No.
0: To send
Assign the Sender start condition to the trunk
route.
•
(1)
(2)
Y=20
00-63: Trunk Route No.
15 : Timing Start
A
CM35
B
TRUNK DATA PROGRAMMING (For Adjunct Analog)