CHAPTER 3 SYSTEM DATA PROGRAMMING
– 130 –
NWA-008855-001 Rev.1.0
avch3001.fm
Announcement-PS No Answer/Announcement-PS Out of Cell
DESCRIPTION DATA
Assign a Digital Announcement Trunk (DAT)
card number to the required LEN.
NOTE 1: The DAT card number must be as-
signed to the first LEN (Level 0), the
third LEN (Level 2), the fifth LEN
(Level 4), and the seventh LEN (Lev-
el 6) of each LT slot.
NOTE 2: EB000 and EB001 are dedicated to
built-in Digital Announcement
Trunk of MP card.
(1)
(2)
XX ZZZ (LEN)
XX : 00-59: FP No.
ZZZ: 000-127: Port No.
EB002-EB127: Digital Announcement
Trunk Card No.
For FP No. 00 : EB002-EB031
For FP No. 01 : EB032-EB063
For FP No. 02 : EB064-EB095
For FP No. 03 : EB096-EB127
NONE : No data
Assign a tenant number to a PS Virtual station
number.
(1)
(2)
Y=04
X-XXXXXXXX: Virtual Station No. as-
signed by CM14
00-63: Tenant 00-63
Specify whether RBT is sent when the called
PS is out of cell or the power is off.
NOTE: CM08>503 is effective only for Sta-
tion-to-Station call.
(1)
(2)
503
0: Not sent
1: To send
Provide PS No-Answer feature. (1)
(2)
504
0: Available
Specify the type of No-Answer Timer. (1)
(2)
085
0: No-Answer timer (CM41
Y=0>86)
1: No-Answer timer (CM41
Y=0>01)
Specify the message reply timer for An-
nouncement-PS No Answer.
(1)
(2)
Y=0
01
01-30: 4-120 seconds
(4 second increments)
If no data is set, the default setting is 32-36 sec-
onds.
START
CM14
CM12
CM08
CM41