CHAPTER 3 SYSTEM DATA PROGRAMMING
– 131 –
NWA-008855-001 Rev.1.0
avch3001.fm
DESCRIPTION DATA
Specify the duration of message for An-
nouncement-PS No Answer.
(1)
(2)
Y=0
75
01-99: 4-396 seconds
(4 second increments)
If no data is set, the default setting is 116-120
seconds.
Specify the duration of message for An-
nouncement-PS Out of Cell/PS Power Off.
(1)
(2)
Y=0
84
01-99: 4-396 seconds
(4 second increments)
If no data is set, the default setting is 116-120
seconds.
Specify the message reply timer for An-
nouncement-PS No Answer.
NOTE: CM41 Y=0>01 is effective only
when CM08>085 is set to 0.
(1)
(2)
Y=0
86
01-99: 4-396 seconds
(4 second increments)
If no data is set, the default setting is 36-40 sec-
onds.
Specify the message reply timer for An-
nouncement-PS Out of Cell/PS Power Off.
(1)
(2)
Y=0
85
01-99: 4-396 seconds
(4 second increments)
If no data is set, the default setting is 8-12 sec-
onds.
Provide the Announcement Service.
(1)
(2)
Y=5
00: PS No-Answer
02: PS Out of Cell/PS Power Off
0500: To provide
Assign the function for each Digital An-
nouncement Trunk.
(1)
(2)
Y=00
002-127: Digital Announcement Trunk
Card No. (EB002-EB127)
1300-1363: PS No Answer Message Group
No. 00-63
1500-1563: PS Out of Cell/PS Power Off
Message Group No. 00-63
A
CM41
CM48
CM49
B
WCS FEATURE PROGRAMMING

Table of Contents

Other manuals for NEC NEAX 2000 IPS