CHAPTER 3 SYSTEM DATA PROGRAMMING
– 97 –
NWA-008855-001 Rev.1.0
avch3001.fm
Initial Set Up for Legacy CS
DESCRIPTION DATA
Assign an AP number to the CSH card.
The AP number must match the SENSE switch
settings on the CSH card.
(1)
(2)
Y=0
04-15, 20-31: AP No.
29: CSH card
Assign a CS number to the required LEN.
NOTE 1: Do not assign the same CS number
as the CS number that is assigned to
the IP-CS by CM14 second data
EEAXXX.
NOTE 2: The CS number must be assigned to
the first LEN (Level 0) and the third
LEN (Level 2) of each LT slot.
NOTE 3: When changing all CS numbers ac-
commodated in same CSI by this
command, clear the D channel data
path between the CSH and CSI by
CM06 Y=18 beforehand.
NOTE 4: If the CS number is changed or
cleared by this command, all CS
data assigned by CMAD change to
each initial data. Assign again all
CS data by CMAD.
(1)
(2)
XX ZZZ (LEN)
XX : 00-59: FP No.
ZZZ: 000-127: Port No.
EE 3 XXX
XXX: 000-255 (CS No.)
START
CM05
INITIAL
CM14
A
CS DATA PROGRAMMING